Iranian Journal of Radiology

Published by: Kowsar

Dual-Source Computed Tomography Evaluation of Children with Congenital Pulmonary Valve Stenosis

Zhanguo Sun 1 , 2 , Wenjian Xu 1 , * , Shuran Huang 2 , Yueqin Chen 2 , Xiang Guo 2 and Zhitao Shi 2
Authors Information
1 Department of Radiology, Affiliated Hospital of Qingdao University, Qingdao City, China
2 Shandong Provincial Key Laboratory of Cardiac Disease Diagnosis and Treatment, Affiliated Hospital of Jining Medical University, Jining, China
Article information
  • Iranian Journal of Radiology: April 01, 2016, 13 (2); e34399
  • Published Online: March 1, 2016
  • Article Type: Research Article
  • Received: November 5, 2015
  • Revised: December 22, 2015
  • Accepted: January 5, 2016
  • DOI: 10.5812/iranjradiol.34399

To Cite: Sun Z, Xu W, Huang S, Chen Y, Guo X, et al. Dual-Source Computed Tomography Evaluation of Children with Congenital Pulmonary Valve Stenosis, Iran J Radiol. 2016 ; 13(2):e34399. doi: 10.5812/iranjradiol.34399.

Abstract
Copyright © 2016, Tehran University of Medical Sciences and Iranian Society of Radiology. This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/) which permits copy and redistribute the material just in noncommercial usages, provided the original work is properly cited.
1. Background
2. Objectives
3. Patients and Methods
4. Results
5. Discussion
Acknowledgements
Footnotes
References
  • 1. Yang X, Yi Z. Pediatrics. 2005;
  • 2. Warnes CA, Williams RG, Bashore TM, Child JS, Connolly HM, Dearani JA, et al. Acc/aha 2008 guidelines for the management of adults with congenital heart disease: Executive summary. J Am Coll Cardiol. 2008; 52(23): 1890-947[DOI]
  • 3. Chen JJ, Manning MA, Frazier AA, Jeudy J, White CS. CT angiography of the cardiac valves: normal, diseased, and postoperative appearances. Radiographics. 2009; 29(5): 1393-412[DOI][PubMed]
  • 4. Groenink M. Response to the letter entitled "Cardiac reserve in pulmonary stenosis: role of multimodality imaging". Int J Cardiol. 2013; 167(6): 3036-7[DOI][PubMed]
  • 5. Nie P, Wang X, Cheng Z, Ji X, Duan Y, Chen J. Accuracy, image quality and radiation dose comparison of high-pitch spiral and sequential acquisition on 128-slice dual-source CT angiography in children with congenital heart disease. Eur Radiol. 2012; 22(10): 2057-66[DOI][PubMed]
  • 6. Johnson TR, Nikolaou K, Wintersperger BJ, Leber AW, von Ziegler F, Rist C, et al. Dual-source CT cardiac imaging: initial experience. Eur Radiol. 2006; 16(7): 1409-15[DOI][PubMed]
  • 7. Li j, Duan Y, Wang X, Wu L, Cheng Z, Wu D, et al. Clinical application of dual-source CT coronary artery angiography [J]. Chinese J Med Imag Tech. 2009; 5: 29
  • 8. Flohr TG, McCollough CH, Bruder H, Petersilka M, Gruber K, Suss C, et al. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol. 2006; 16(2): 256-68[DOI][PubMed]
  • 9. Yildiz O, Altin FH, Kaya M, Ozyilmaz I, Guzeltas A, Erek E. Left coronary artery stenosis causing left ventricular dysfunction in two children with supravalvular aortic stenosis. World J Pediatr Congenit Heart Surg. 2015; 6(2): 311-6[DOI][PubMed]
  • 10. Scheffel H, Alkadhi H, Plass A, Vachenauer R, Desbiolles L, Gaemperli O, et al. Accuracy of dual-source CT coronary angiography: First experience in a high pre-test probability population without heart rate control. Eur Radiol. 2006; 16(12): 2739-47[DOI][PubMed]
  • 11. Raff GL, Gallagher MJ, O'Neill WW, Goldstein JA. Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol. 2005; 46(3): 552-7[DOI][PubMed]
  • 12. Moser M, Bosserhoff AK, Hunziker EB, Sandell L, Fassler R, Buettner R. Ultrastructural cartilage abnormalities in MIA/CD-RAP-deficient mice. Mol Cell Biol. 2002; 22(5): 1438-45[PubMed]
  • 13. Baig SA, Saeed Z, Fatima A, Chagani H, Aziz S. Double outlet right ventricle, atrioventricular canal defect with severe pulmonary artery stenosis: a rare cyanotic congenital heart disease. J Pak Med Assoc. 2014; 64(8): 980-2[PubMed]
  • 14. Rigsby CK, Hilpipre N, McNeal GR, Zhang G, Boylan EE, Popescu AR, et al. Analysis of an automated background correction method for cardiovascular MR phase contrast imaging in children and young adults. Pediatr Radiol. 2014; 44(3): 265-73[DOI][PubMed]
  • 15. Wang D, Liu C, Liu K, Chen Q, Wang S, Liang C. Study of demonstrating the panorama and correlative measurements for bony semicircular canals by double oblique MPR using multi-slice CT. Yixue Yingxiangxue Zazhi. 2005; 15(7): 523-4
  • 16. Thakkar B, Madan T, Ashwal AJ. Transcatheter right ventricular outflow tract stenting in children with postoperative infundibular stenosis and preserved pulmonary valve function. J Invasive Cardiol. 2013; 25(7)-4[PubMed]
  • 17. Friedman KG, McElhinney DB, Rhodes J, Powell AJ, Colan SD, Lock JE, et al. Left ventricular diastolic function in children and young adults with congenital aortic valve disease. Am J Cardiol. 2013; 111(2): 243-9[DOI][PubMed]
  • 18. Anwar AM, Soliman O, van den Bosch AE, McGhie JS, Geleijnse ML, ten Cate FJ, et al. Assessment of pulmonary valve and right ventricular outflow tract with real-time three-dimensional echocardiography. Int J Cardiovasc Imaging. 2007; 23(2): 167-75[DOI][PubMed]
  • 19. Ling J, Xie R, Xu L. Percutaneous balloon pulmonary valvuloplasty and results of mid-long term follow up. Zhonghua xin xue guan bing za zhi. 2002; 31(5): 323-5
  • 20. Liu XG, Wu KH, Shi C, Li XF, Wang ZY, Tang Z. [The clinical results of right ventricular outflow tract reconstruction with a transannular patch of autologous pericardium]. Zhonghua Yi Xue Za Zhi. 2007; 87(8): 553-5[PubMed]
  • 21. Son JY, Ko SM, Choi JW, Song MG, Hwang HK, Lee SJ, et al. Measurement of the ascending aorta diameter in patients with severe bicuspid and tricuspid aortic valve stenosis using dual-source computed tomography coronary angiography. Int J Cardiovasc Imaging. 2011; 27 Suppl 1: 61-71[DOI][PubMed]
  • 22. Liu Y. Cardiology Diagnostic Imaging. Hefei. Anhui Science and Technology Press. 2000;
  • 23. McAleer E, Kort S, Rosenzweig BP, Katz ES, Tunick PA, Phoon CK, et al. Unusual echocardiographic views of bicuspid and tricuspid pulmonic valves. J Am Soc Echocardiogr. 2001; 14(10): 1036-8[PubMed]
  • 24. Bauner K, Kozlik-Feldmann R. [Minimally invasive pulmonary valve replacement in pediatric patients: importance of imaging]. Radiologe. 2013; 53(10): 880-5[DOI][PubMed]
  • 25. Lam Y, Kaya MG, Goktekin O, Gatzoulis MA, Li W, Henein MY. Restrictive right ventricular physiology: its presence and symptomatic contribution in patients with pulmonary valvular stenosis. J Am Coll Cardiol. 2007; 50(15): 1491-7
  • 26. Perri G, Polito A, Esposito C, Albanese SB, Francalanci P, Pongiglione G, et al. Early and late failure of tissue-engineered pulmonary valve conduits used for right ventricular outflow tract reconstruction in patients with congenital heart disease. Eur J Cardiothorac Surg. 2012; 41(6): 1320-5[DOI][PubMed]
  • 27. Rajiah P, Nazarian J, Vogelius E, Gilkeson RC. CT and MRI of pulmonary valvular abnormalities. Clin Radiol. 2014; 69(6): 630-8[DOI][PubMed]
  • 28. Luo Y, Yu J, Li X, Chen D, Xu Z, Peng L. [Value of dual-source CT in diagnosis of single ventricle]. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2013; 30(3): 508-12[PubMed]
  • 29. Ranji Amjad M, Abbasi M, Farzanehfar S. Lung Perfusion SPECT: Application in a Patient with Tetralogy of Fallot and Suspected Pulmonary Thromboemboli. Iran J Radiol. 2015; 12(2)[DOI]
  • 30. Sun HY, Boe J, Rubesova E, Barth RA, Tacy TA. Fetal MRI correlates with postnatal CT angiogram assessment of pulmonary anatomy in tetralogy of Fallot with absent pulmonary valve. Congenit Heart Dis. 2014; 9(4)-9[DOI][PubMed]
Creative Commons License Except where otherwise noted, this work is licensed under Creative Commons Attribution Non Commercial 4.0 International License .

Search Relations:

Author(s):

Article(s):

Create Citiation Alert
via Google Reader

Readers' Comments